Pyralux® TK Kapton® & fluoropolymer bond ply features Kapton® polyimide film, coated on both sides with a proprietary B-staged modified acrylic adhesive. This bond ply can be used to encapsulate etched details for environmental protection and electrical insulation. Using bond ply can eliminate a layer of Kapton® dielectric and a layer of adhesive in low-layer count multilayer constructions.
| Property Group | Property Name | Value | Test Method |
|---|---|---|---|
| Dielectric | Dielectric Constant (Dk) 10GHz | 2.3 Normal, 2.6 In-plane | ASTM D2520 / IPC-TM-650 2.5.5.3 |
| Dielectric Strength (V/μm) | 190 | ASTM D149 | |
| Loss Tangent (Df) 10GHz | 0.0015 | ASTM D2520 / IPC-TM-650 2.5.5.3 | |
| Environmental | Moisture Absorption (%) | 0.3 | IPC-TM-650 2.6.2 |
| Property Name | Form Factor | Package | Adhesive Type | Dielectric Thickness (μm) | Dielectric Thickness (mil) | Adhesive Thickness (μm) | Adhesive Thickness (mil) |
|---|---|---|---|---|---|---|---|
| TK252525 | Bond ply | Roll | Polyimide | 25.0 | 1.00 | 25.0 | 1.0 |
| TK255025 | Bond ply | Roll | Polyimide | 25.0 | 1.00 | 50.0 | 2.0 |
| TK445044 | Bond ply | Roll | Polyimide | 44.0 | 1.75 | 50.0 | 2.0 |